Key Findings in This Report

• • Achieves >95% reduction in waste storage and transportation volumes, eliminating risks associated with long-distance hauling and centralized treatment. • • Maintains combustion temperatures: C1 at 740–800°C, C2 at 1100–1105°C, C3 at 1120–1124°C, ensuring complete destruction of organics and dioxin suppression. • • Emission levels during tests: CO ≤ 5 mg/m³, NOx ≤ 10 mg/m³, SOx ≤ 1 mg/m³, and dioxins below 0.1 ng-TEQ/m³, meeting stringent environmental standards. • • Handles variable waste feed rates (1.5–8.0 kg/h) with stable operation, demonstrating robustness for real-world medical waste variability.
Download Full PDF: Design and Implementation of an Energy-Saving Onsite Thermal Treatment System for Hazardous Medical Organic Waste Liquid | SinoTechIntel | SinoGreenTech