SCIENCE CHINA Materials•2026•DOI: 10.1007/s40843-026-4441-7
Early detection of kidney injury remains difficult because routine clinical indicators often lag behind tissue damage. Here we report uNP-CH1055, an ultrasmall renal-clearable NIR-II fluorescent nanoprobe for non-invasive imaging of kidney injury in vivo. uNP-CH1055 formed stable nanoparticles with a hydrodynamic diameter of 3.3 nm, showed good photostability, enabled low-background imaging under a 1200 nm long-pass filter, and underwent rapid renal clearance after intravenous administration. It also exhibited favorable biocompatibility in both cellular and animal studies. In three mechanistically distinct models of renal injury, cisplatin-induced acute kidney injury, ischemia–reperfusion injury and unilateral ureteral obstruction, renal fluorescence increased with injury severity and closely paralleled biochemical and histological indicators, including blood urea nitrogen, serum creatinine, KIM-1 and TUNEL-based readouts. These results identify uNP-CH1055 as a renal-clearable NIR-II probe for early and quantitative assessment of kidney injury across different pathological settings.
SCIENCE CHINA Materials•2026•DOI: 10.1007/s40843-026-4426-y
Biomedical Mg alloys are candidate biodegradable metals for orthopedic and cardiovascular implants, yet their in vivo service life is governed by coupled mechanical-chemical attack that accelerates loss of mechanical integrity. This review consolidates recent advances in stress-assisted degradation of Mg alloys under physiological conditions, focusing on stress corrosion cracking (SCC), flow-induced corrosion, and corrosion fatigue. Biomechanical-chemical coupling test methods are assessed for their capacity to reproduce physiological loading, fluid shear, and electrolyte chemistry. Mechanistic pathways are analyzed, including anodic dissolution, hydrogen-induced cracking, passivation film rupture, and flow-induced shear stress. Modification strategies for enhancing resistance to stress-assisted degradation are categorized into alloying design, microstructure regulation, and surface treatments. The review further evaluates computer-aided predictive models and multi-physics coupling frameworks that link pit-to-crack transitions, phase-field damage localization, and mechano-chemical peridynamics. Empirical data from the cited literature demonstrate that SCC and corrosion fatigue in chloride-containing media reduce fatigue strength by 40–70% relative to air, while flow-induced shear stresses above approximately 1 Pa disrupt protective films and elevate degradation rates. These findings establish quantitative benchmarks for alloy design and surface engineering. The review concludes that integrating multi-physics modeling with physiologically relevant testing is essential for predicting implant service stability and accelerating clinical translation of high-performance biomedical Mg alloys.
Journal of Fuel Chemistry and Technology•2026•DOI: 10.1016/S1872-5813(25)60600-1
The service life of refractory bricks in the slag tapping hole of entrained-flow gasifiers is a critical bottleneck for long-term stable operation. This study investigated the damage mechanism of high chromia refractories in four commercial coal-water slurry gasifiers by analyzing gasification coal samples and corroded refractory bricks. Slag characteristics, including crystallization and viscosity-temperature behavior, were evaluated. Results revealed that low-viscosity slag induces more severe refractory damage. To mitigate slag crystallization risk, a safe slag tapping temperature range is recommended as tICT−t2.5 when tICT exceeds t25. Interior morphology of corroded bricks exhibited cracks, primarily attributed to molten slag penetration and subsequent reactions with refractory material. SEM-EDS analysis of slag-aggregate and slag-matrix interfaces identified reduction in Cr2O3 content as the earliest damage characteristic. XRD detected no zirconium-containing spinel in cracks, indicating that thermal expansion mismatch between newly formed phases and the refractory matrix drives crack propagation. A damage mechanism is proposed: initial Cr2O3 depletion compromises both matrix and aggregate, facilitating slag ingress and new phase formation, ultimately leading to structural failure. Early detection or prevention of Cr2O3 reduction is essential to prolong refractory service life.
Journal of Fuel Chemistry and Technology•2026•DOI: 10.3724/2097-213X.2025.JFCT.0029
Pingshuo coal ash, characterized by high silicon-aluminum content (Si+Al >85%) and low Si/Al ratio (<1.5), exhibits ash fusion temperatures (AFTs) exceeding 1550 °C, rendering it unsuitable for entrained-flow gasifiers. This study investigates the effect of calcium-sodium composite flux on ash fusibility and mineral transformation. X-ray diffraction (XRD) and FactSage thermodynamic simulations were employed to analyze mineral evolution, while molecular dynamics (MD) simulations revealed the underlying melting mechanism. Results show that adding 20% composite flux (CaO/Na2O) lowers AFTs more effectively than equivalent additions of CaO or Na2O alone, indicating a synergistic effect. At a CaO/Na2O ratio of 3:7, the flow temperatures (FT) of two Pingshuo coal ashes decreased to 1377 °C and 1279 °C, respectively. The composite flux promotes reactions between quartz and Na2O/CaO, forming low-melting-point minerals such as nepheline, albite, and gehlenite, while inhibiting mullite formation. Additionally, Na+ disrupts the silicate network, inducing Ca2+ to preferentially coordinate with [AlO4]5- tetrahedra, further breaking Si-O-Si bonds. MD simulations show that atomic diffusion, quantified by mean square displacement (MSD), is significantly enhanced below 1600 K with composite flux addition compared to single fluxes. These findings provide a mechanistic basis for optimizing flux formulations to enable efficient gasification of high-AFT coals.
SCIENCE CHINA Materials•2026•DOI: 10.1007/s40843-025-4045-x
The release of radioactive iodine from nuclear accidents and nuclear medicine poses significant environmental and health risks. Here, we report the design and synthesis of two cross-linked macrocycle-based porous organic polymers (P1 and P2) with different functionalities for efficient and rapid capture of radioactive iodine. P1 achieves complete iodine adsorption within 5 minutes, with an exceptional adsorption rate constant (k_obs) of 18.92 g g−1 min−1 (8.24 g g−1 min−1 for P2), representing a record-high iodine removal rate among state-of-the-art porous organic polymers. P1 demonstrates superior iodine adsorption efficacy in dynamic flow-through experiments, achieving a remarkable efficiency of 96.4% for radioactive 131I removal, greatly minimizing radiation contamination. Experimental and modelling techniques reveal that the superior iodine adsorption performance originates from electron-rich functional groups, hydrophobic surface, and porous structure of P1, thus exhibiting remarkable iodine capture capabilities through charge transfer, halogen bonding, and hydrophobic effects. The adsorbents show excellent stability and performance under complex and harsh conditions (pH 2–10) and can be easily regenerated, confirming their excellent reusability and potential for practical applications.